Bug #10596

System Display "System Unavailable" When Checker Approve on Changes at Company Details.

Added by Erni Suhaireen Zulkifli over 4 years ago. Updated over 4 years ago.

Status:Work Completed-End life cycleStart date:January 21, 2020
Priority:NormalDue date:January 22, 2020
Assignee:Erni Suhaireen Zulkifli% Done:

100%

Category:-Spent time:-
Target version:-

Description

Bug: System display "System Unavailable" when Checker approve on changes at Company Details.

Role: IBAM Checker

Path: IBAM>BIB>Authorization>Approval>BIB Authorization

Step to Reproduce:
1. Login as checker and approve on changes made by Maker on field:
- Module Type
- Single User/Multiple User
- Allow Viewer

Current Result:
Refer attached file.

0004.jpg (87 KB) Erni Suhaireen Zulkifli, January 21, 2020 10:12

History

#1 Updated by Bramantyo Pujo Wiyono over 4 years ago

  • Status changed from New - Begin Life Cycle to Investigation
  • % Done changed from 0 to 90

Cause:
Broken data on user 'aaziapp'
User didt exist on TB_AM_USER
Solution:
Try on different company to make sure this didt happen

#2 Updated by Bramantyo Pujo Wiyono over 4 years ago

  • Status changed from Investigation to Internal Testing
  • Assignee changed from Bramantyo Pujo Wiyono to Erni Suhaireen Zulkifli

#3 Updated by Erni Suhaireen Zulkifli over 4 years ago

  • Status changed from Internal Testing to Work Completed-End life cycle
  • % Done changed from 90 to 100

Issue has retest with different company and successfully passed