Bug #11711
[MOD002: Admin User Maintenance] Validation for User Access - Create User Admin
Status: | Work Completed-End life cycle | Start date: | April 22, 2021 | |
---|---|---|---|---|
Priority: | Normal | Due date: | ||
Assignee: | Lizahwati Basirun | % Done: | 100% | |
Category: | - | Spent time: | - | |
Target version: | - |
Description
Login > Home > ADMIN > Admin User Maintenance > Create - details screen
- Uncheck checkbox for User Access
- Click on Next button
Actual Result:
System allow proceed to confirm page
Expected Result:
System throw error message "User Access is required"
History
#1 Updated by Bramantyo Pujo Wiyono over 3 years ago
- Status changed from New - Begin Life Cycle to Internal Testing
- Assignee changed from Bramantyo Pujo Wiyono to Lizahwati Basirun
- % Done changed from 0 to 80
#2 Updated by Lizahwati Basirun over 3 years ago
- Status changed from Internal Testing to Work Completed-End life cycle
- % Done changed from 80 to 100
Successfully tested.