Bug #3693

Bii:UAT- Defect ID 151 Sev 2 : Already assigned some tokens to porovider (Indonesia) in RCAS. But unable to prebind a single token from RCMS.

Added by Man Siew Yong almost 11 years ago. Updated almost 11 years ago.

Status:Closed - End of life cycleStart date:October 01, 2013
Priority:NormalDue date:October 01, 2013
Assignee:-% Done:

0%

Category:-Spent time:-
Target version:-

Description

Already assigned some tokens to porovider (Indonesia) in RCAS. But unable to prebind a single token from RCMS.
trx time: 17:20 PM Jkt Time

CASRequest.txt Magnifier (605 Bytes) Man Siew Yong, October 01, 2013 18:33

CASRespond.txt Magnifier (451 Bytes) Man Siew Yong, October 01, 2013 18:33

clb_picture_1.jpeg (38.7 KB) Man Siew Yong, October 01, 2013 18:33

History

#1 Updated by Man Siew Yong almost 11 years ago

  • Due date set to October 01, 2013
  • Status changed from New - Begin Life Cycle to Pending Customer Feedback
  • Assignee changed from Anwar Khairul to Man Siew Yong

Fixed by Boby and Anwar
1 OCT: Fixed and release 00012

Pending on User retest

#2 Updated by Anonymous almost 11 years ago

please provide the resolution for all defects that we fixed, how did you fix it. Maybank team will follow up this (when they hv some free time) if this information did not indicate in the HPQC, they have been highlighted this before in 1 of the meeting.

#3 Updated by Hartanto Boby almost 11 years ago

Issue in converting the provider. Update the converter to fix the issue

#4 Updated by Man Siew Yong almost 11 years ago

  • Status changed from Pending Customer Feedback to Closed - End of life cycle
  • Assignee changed from Man Siew Yong to Anonymous

11 OCT: Release 00022 User retest done

Also available in: Atom PDF