Support #10810

[SCP ID :##5354##] : Device Pairing error

Added by Zahir Abd Latif over 4 years ago. Updated almost 4 years ago.

Status:Work Completed-End life cycleStart date:May 28, 2020
Priority:NormalDue date:
Assignee:Zahir Abd Latif% Done:

90%

Category:-Spent time:-
Target version:-

Description

Hi,
Kindly attend below request:

Device pairing error due to invalid check digit for BSN account number


Related issues

Related to BSN CDB Support - Support #10796: [SCP ID :##5342##] : Invalid Check Digit Work Completed-End life cycle May 19, 2020

History

#1 Updated by Najmi Pasarudin over 4 years ago

  • Status changed from New - Begin Life Cycle to User Acceptance Test
  • Assignee changed from Najmi Pasarudin to Nurul Athira Abdul Rahim
  • % Done changed from 0 to 90

#2 Updated by Najmi Pasarudin over 4 years ago

Issue:
BSN account number ending with zero causing error "Invalid Account Number"

Finding:
CDB check digit missing a validation.

Solution:
Add the validation formula when check digit.
Deploy bsn-restful for mobile.

#3 Updated by Najmi Pasarudin over 4 years ago

  • Status changed from User Acceptance Test to Pending Review

Deployed to Production on 29/05/2020

#4 Updated by Nurul Athira Abdul Rahim almost 4 years ago

  • Status changed from Pending Review to Work Completed-End life cycle
  • Assignee changed from Nurul Athira Abdul Rahim to Zahir Abd Latif

Also available in: Atom PDF