Bug #12432
[BIF-31460] System can't display error message on field Notice Tilte (Spesial Character)
Status: | Work Completed-End life cycle | Start date: | October 21, 2021 | |
---|---|---|---|---|
Priority: | Normal | Due date: | October 22, 2021 | |
Assignee: | Siti Norahayu Mohd Desa | % Done: | 100% | |
Category: | - | Spent time: | - | |
Target version: | - |
Description
Change Notice Title to alphanumeric and space as per SRS
Step :
1. Access to Content Management screen
2. Click on “Select Content” menu then select “Notices” (System displays Notices Content type by default )
3. Click on specific Notices Category Name link
4. Click on button “Create Content”
5. Input special character on Notice Title
6. Click on Next Button
Expected :
Step 2: System displays Notices Category screen
Step 3: System displays Notices Content List tab
Step 4: System displays Create Notices Content Page
Step 6: System displays error message - Please input a valid value
Note :
Actual : System can't validasi in field Notice Title (Input Special Char)
Expect : System can validation in Field Notice Title with "error message"
History
#1 Updated by Siti Norahayu Mohd Desa almost 3 years ago
- Description updated (diff)
#2 Updated by Bramantyo Pujo Wiyono almost 3 years ago
- Status changed from New - Begin Life Cycle to Internal Testing
- Assignee changed from Bramantyo Pujo Wiyono to Siti Norahayu Mohd Desa
- % Done changed from 0 to 80
will deploy on 2.0.60-ga
#3 Updated by Siti Norahayu Mohd Desa almost 3 years ago
- Status changed from Internal Testing to Development / Work In Progress
- Assignee changed from Siti Norahayu Mohd Desa to Bramantyo Pujo Wiyono
Tested & Failed.
Title still able to input special char.
Expected result : Change Notice Title to alphanumeric and space as per SRS
#4 Updated by Bramantyo Pujo Wiyono almost 3 years ago
- Status changed from Development / Work In Progress to Internal Testing
- Assignee changed from Bramantyo Pujo Wiyono to Siti Norahayu Mohd Desa
will deploy on 2.0.61-ga
#5 Updated by Siti Norahayu Mohd Desa almost 3 years ago
- Status changed from Internal Testing to Work Completed-End life cycle
- % Done changed from 80 to 100
Issue have been closed by pak dhiko on 25 Oct 2021