Bug #12615
[BIF - 45128] Cannot login 300 users concurrently, error 502
Status: | Work Completed-End life cycle | Start date: | November 22, 2021 | |
---|---|---|---|---|
Priority: | Normal | Due date: | December 01, 2021 | |
Assignee: | Chun Feng Lim | % Done: | 100% | |
Category: | - | Spent time: | - | |
Target version: | - |
Description
Description:
Performed using URL:
https://bifastportalnft.corp.bi.go.id/bifast-portal-non/common/Login.do
143 failed logins out of 300 (attachment TrE 211116 - 2124 - Statistics - Failure Rate)
the top failures' error code is 502, the details can be seen in the attachment TrE 211116 - 2124 - Failures
Accessed the web while testing and got a Proxy Error message (attachment TrE 211116 - 2124 - Web Open while test)
the detailed locust test report can be seen in attachment report_1637073218.1626043
Muhammad Azizi Nun's comment:
if concurrent login is failed, we can not do liquidity status enquiry and threshold details edit
History
#1 Updated by Nurul Akmal almost 3 years ago
- Subject changed from Cannot login 300 users concurrently, error 502 to [BIF - 45128] Cannot login 300 users concurrently, error 502
#2 Updated by Siti Norahayu Mohd Desa almost 3 years ago
HI CF,
Please update on the progress. TQ
#3 Updated by Siti Norahayu Mohd Desa almost 3 years ago
- Due date set to December 01, 2021
- Status changed from New - Begin Life Cycle to Pending Customer Feedback
- % Done changed from 0 to 100
Re-run the test script using 300 concurrent users. Stop when 300 login successful was shown, repeated for 3 times. No login failure found in result
Send for user verification
#4 Updated by Siti Norahayu Mohd Desa almost 3 years ago
- Status changed from Pending Customer Feedback to Work Completed-End life cycle
Issue have been closed by Pandu on 1 Dec 2021